Catalogue des ouvrages Université de Laghouat
A partir de cette page vous pouvez :
[article] in Revue des sciences et de la technologie > N° 31 [01/10/2015] . - p. 90 Titre : | Monitoring of electromagnetic pollution inside switchyard substation : (case study: El-Hadjar electrical post in Annaba city, Algeria). | Type de document : | texte imprimé | Auteurs : | Wafa Tourab, Auteur ; Abdessalem Babouri, Auteur | Année de publication : | 2015 | Article en page(s) : | p. 90 | Langues : | Français | Mots-clés : | electromagnetic compatibility low frequency electromagnetic fields high voltage power lines electromagnetic pollution international standards | Résumé : | The aim of this paper is to carry out an experimental characterization of the electromagnetic environment beneath a selected circuit of two 220kV power lines inside El-Hadjar electrical post often requiring maintenance. An analytical the calculation method is proposed in order to complete this study. The model of the circuit of lines proposed was constructed using the actual physical dimensions of the towers. It follows a numerical simulation of the field's magnitudes for highest ground clearance levels close to the towers. General conclusions arising from the comparison of the results with relevant reference levels in force for occupational exposure as well as recommendations to ensure workers safety are finally given. |
[article] Monitoring of electromagnetic pollution inside switchyard substation : (case study: El-Hadjar electrical post in Annaba city, Algeria). [texte imprimé] / Wafa Tourab, Auteur ; Abdessalem Babouri, Auteur . - 2015 . - p. 90. Langues : Français in Revue des sciences et de la technologie > N° 31 [01/10/2015] . - p. 90 Mots-clés : | electromagnetic compatibility low frequency electromagnetic fields high voltage power lines electromagnetic pollution international standards | Résumé : | The aim of this paper is to carry out an experimental characterization of the electromagnetic environment beneath a selected circuit of two 220kV power lines inside El-Hadjar electrical post often requiring maintenance. An analytical the calculation method is proposed in order to complete this study. The model of the circuit of lines proposed was constructed using the actual physical dimensions of the towers. It follows a numerical simulation of the field's magnitudes for highest ground clearance levels close to the towers. General conclusions arising from the comparison of the results with relevant reference levels in force for occupational exposure as well as recommendations to ensure workers safety are finally given. |
|